Turbine meter SM-RI-X
The SM-RI-X is equipped as standard with a lubrication system of all types and a mechanical index with a metal cover. Optionally, all meter sizes can be equipped with an economical medium frequency pulse, achieved within the meter index.
The high temperature turbine flow meter is a state-of-the-art precision instrument designed for preheated gas for power plants. Optical sensors (high frequency receiver) will register two pulses per revolution of the turbine wheel from a special rotating actuator (light corridor) mounted on the main shaft.
Use 4 optical sensors mounted in a special well protection cover that replaces or cleans without removing pressure from the line. The optical interface unit is mounted on the meter in an explosion-proof box.
Meter type | SM-RI-HT | |
Diameter | mm inch |
150 – 200 6 – 8 |
Flow range size | G 1000 – G 1600 | |
Qmax | m³/h cfh |
1600 – 2500 56000 – 88000 |
Extent | p = 0 bar g | 1:20 |
Max. read error (Qt – Qmax) | 1 bar g (Qt = 0.2 Qmax) | ±0.5 % |
Repeatability | % read | < 0.1 % |
Upstream straight pipe | 2 DN | |
Downstream straight pipe | 2 DN | |
Type approval | acc. ISO 9951 | |
Housing material | sferoidno liveno gvožde (do PN 16), čelik | |
Body length | 3 DN | |
Flange ratings | PN ANSI |
100 600 |
Pressure range | MPa g bar g psi g |
0.8 – 8.95 8 – 89.5 115 – 1300 |
Temperature range | environment process |
-10 to +65 °C -10 to +170 °C |
Intrusion protection | IP 67 | |
LF sensor | standard | – |
HF-sensor | optional | 2 |
Lubrication | oil pump |
One of the few turbine meters in the world specially designed for measuring ethylene and other critical gases. High-quality ceramic bearings, double lubrication and advanced hydrodynamic design give superior performance to other measuring systems.
Meter type | SM-RI-P | |
Diameter | mm inch |
50 – 250 2 – 10 |
Flow range size | G 40 – G 2500 | |
Qmax | m³/h cfh |
65 – 4000 5800 – 141,000 |
Extent | p = 0 bar g p = 20 bar g p = 50 bar g |
1:20 1:50 1:100 |
Max. read error (Qt – Qmax) | 1 bar g (Qt = 0.2 Qmax) | ±0.5 % |
Repeatability | % read | < 0.1 % |
Upstream straight pipe | 2 DN | |
Downstream straight pipe | 2 DN | |
Type approval | Yes | |
Housing material | steel ASTM A 350 LF2 | |
Body length meter | depending on the scope | |
Flange ratings | PN ANSI |
10 – 100 125 – 600 |
Pressure range | MPa g bar g psi g |
0 – 13 0 – 130 0 – 1885 |
Temperature range | environment process |
-10 to +65 °C -20 to +65 °C |
Intrusion protection | IP 61 | |
LF sensor | standard | – |
HF-sensor | optional | 2 |
Lubrication | standard0 | 2 x oil pump |