{"id":5240,"date":"2021-11-24T18:14:38","date_gmt":"2021-11-24T18:14:38","guid":{"rendered":"https:\/\/fagas.ba\/product\/abolute-encoder-ae5\/"},"modified":"2021-11-24T18:14:39","modified_gmt":"2021-11-24T18:14:39","slug":"abolute-encoder-ae5","status":"publish","type":"product","link":"https:\/\/fagas.ba\/en\/product\/abolute-encoder-ae5\/","title":{"rendered":"ABOLUTE-ENCODER AE5"},"content":{"rendered":"<p>[et_pb_section fb_built=&#8221;1&#8243; _builder_version=&#8221;3.22&#8243; custom_padding=&#8221;0px||||false|false&#8221; da_is_popup=&#8221;off&#8221; da_exit_intent=&#8221;off&#8221; da_has_close=&#8221;on&#8221; da_alt_close=&#8221;off&#8221; da_dark_close=&#8221;off&#8221; da_not_modal=&#8221;on&#8221; da_is_singular=&#8221;off&#8221; da_with_loader=&#8221;off&#8221; da_has_shadow=&#8221;on&#8221; da_disable_devices=&#8221;off|off|off&#8221;][et_pb_row _builder_version=&#8221;3.25&#8243; background_size=&#8221;initial&#8221; background_position=&#8221;top_left&#8221; background_repeat=&#8221;repeat&#8221; width=&#8221;100%&#8221; custom_padding=&#8221;0px||0px||false|false&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;3.25&#8243; custom_padding=&#8221;|||&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_wc_breadcrumb admin_label=&#8221;Woo Breadcrumb&#8221; _builder_version=&#8221;3.0.47&#8243;][\/et_pb_wc_breadcrumb][\/et_pb_column][\/et_pb_row][et_pb_row column_structure=&#8221;1_2,1_2&#8243; _builder_version=&#8221;3.25&#8243; background_size=&#8221;initial&#8221; background_position=&#8221;top_left&#8221; background_repeat=&#8221;repeat&#8221; width=&#8221;100%&#8221; custom_padding=&#8221;0px||||false|false&#8221;][et_pb_column type=&#8221;1_2&#8243; _builder_version=&#8221;3.25&#8243; custom_padding=&#8221;|||&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_wc_images _builder_version=&#8221;4.7.4&#8243; _module_preset=&#8221;default&#8221;][\/et_pb_wc_images][\/et_pb_column][et_pb_column type=&#8221;1_2&#8243; _builder_version=&#8221;3.25&#8243; custom_padding=&#8221;|||&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_wc_title _builder_version=&#8221;3.0.47&#8243;][\/et_pb_wc_title][et_pb_wc_description _builder_version=&#8221;3.0.47&#8243;][\/et_pb_wc_description][et_pb_wc_meta _builder_version=&#8221;3.0.47&#8243;][\/et_pb_wc_meta][\/et_pb_column][\/et_pb_row][et_pb_row _builder_version=&#8221;3.25&#8243; background_size=&#8221;initial&#8221; background_position=&#8221;top_left&#8221; background_repeat=&#8221;repeat&#8221; width=&#8221;100%&#8221;][et_pb_column type=&#8221;4_4&#8243; _builder_version=&#8221;3.25&#8243; custom_padding=&#8221;|||&#8221; custom_padding__hover=&#8221;|||&#8221;][et_pb_divider color=&#8221;#D8D8D8&#8243; divider_position=&#8221;center&#8221; _builder_version=&#8221;4.7.4&#8243; _module_preset=&#8221;default&#8221;][\/et_pb_divider][et_pb_tabs module_class=&#8221;vertical-tabs2&#8243; _builder_version=&#8221;4.7.4&#8243; _module_preset=&#8221;default&#8221;][et_pb_tab title=&#8221;ACM M-BUS WIRE&#8221; _builder_version=&#8221;4.7.4&#8243; _module_preset=&#8221;default&#8221;]<\/p>\n<p>The ACM M-BUS WIRE communication module can be connected to the Absolute ENCODER AE5 and enables wired M-Bus communication. The ACM M-BUS WIRE communication module can be connected to the M-Bus home network, which communicates using a standard M-Bus or M-Bus OMS (open metering system). ACM M-BUS WIRE supports both protocol variants.<\/p>\n<p><strong>Standard M-Bus<\/strong><\/p>\n<ul class=\"stup-list\">\n<li>The standard M-Bus protocol in accordance with DIN EN 13757-2: 2004 (connection layer) and DIN EN 13757-3: 2004 for meters and remote meter reading has been applied.<\/li>\n<li>In order for the ACM M-BUS WIRE to be used in the M-Bus protocol variant, the AE5 must be factory programmed and delivered in the &#8220;M-Bus Standard&#8221; variant)<\/li>\n<\/ul>\n<p><strong>M-Bus according to OMS (open metering system<\/strong><\/p>\n<ul class=\"stup-list\">\n<li>M-Bus protocol for data transfer to OMS Vol. 2 is implemented; communication is not encrypted<\/li>\n<li>In order for the ACM M-BUS WIRE to be used in the M-Bus OMS variant, the AE5 must be factory programmed and delivered in the &#8220;Multi-Protocol&#8221; variant.<\/li>\n<\/ul>\n<p><strong>Technical data ACM M-BUS WIRE<\/strong><\/p>\n<ul class=\"stup-list\">\n<li>Housing: IP 54<\/li>\n<li>Ambient temperature: -25 to +55 \u00b0 C<\/li>\n<li>Connection cable design: 2 m flexible, two-core LiYY cable, fireproof according to IEC 60332-1, cross section = 0.25 mm2<\/li>\n<li>The free end of the cable has 2 wire end tubes<\/li>\n<li>Power supply via M-Bus: 3 mA (2 M-Bus loads)<\/li>\n<\/ul>\n<p>[\/et_pb_tab][et_pb_tab title=&#8221;ACM SCR WIRE&#8221; _builder_version=&#8221;4.7.4&#8243; _module_preset=&#8221;default&#8221;]<\/p>\n<p>The cable-based ACM SCR WIRE connects the Absolute CODER AE5 and the receiving unit to the SCR interface (OBIS code numbers according to OMS). Honeywell can supply compatible data loggers and volume conversion devices. Communication is not encrypted.<br \/>Note: To use the ACM SCR WIRE, the AE5 must be factory programmed and shipped in a &#8220;Multi-Protocol&#8221; variant.<\/p>\n<p><strong>Technical data ACM SCR WIRE<\/strong><\/p>\n<ul class=\"stup-list\">\n<li>Housing: IP 54<\/li>\n<li>Ambient temperature: -25 to +55 \u00b0 C<\/li>\n<li>Connection cable design: 2 m flexible, two-core LiYY cable, fireproof according to IEC 60332-1, cross section = 0.25 mm2<\/li>\n<li>The free end of the cable has 2 wire end tubes<\/li>\n<li>Power supply via SCR: 3 mA<\/li>\n<\/ul>\n<p>[\/et_pb_tab][et_pb_tab title=&#8221;ACM 5.X M-BUS RADIO&#8221; _builder_version=&#8221;4.7.4&#8243; _module_preset=&#8221;default&#8221;]<\/p>\n<p>The ACM 5.X M-BUS RADIO communication module transmits the Absolute CODER AE5 meter readings in a one-way basis to a suitable receiving unit &#8211; in Germany, a smart meter counter. The transmission complies with BSI TR-03109. The data is transmitted in encrypted form. The ACM comes fully programmed.<br \/>Note: To use the ACM 5.X M-BUS RADIO, the AE5 must be pre-programmed and supplied in the &#8220;Multi-Protocol&#8221; variant.<\/p>\n<p><strong>Technical data ACM 5.X M-BUS RADIO<\/strong><\/p>\n<ul class=\"stup-list\">\n<li>Housing: IP 54<\/li>\n<li>Ambient temperature: -25 \u00b0 C to +55 \u00b0 C<\/li>\n<li>Storage temperature: -30 \u00b0 C to +60 \u00b0 C<\/li>\n<li>Relative humidity: 0 to 85%<\/li>\n<li>Frequency range: 868 MHz<\/li>\n<li>Protocol: Wireless M-Bus up to OMS generation 4 with safety profile B (mode 7)<\/li>\n<li>Transmission power: about 7 mW (output power 14 dBm)<\/li>\n<li>Transmission: one-way<\/li>\n<li>Transmission range: up to 400 m, depending on the environment<\/li>\n<li>Transmission interval: every 5 minutes<\/li>\n<li>Meter reading update: every 20 minutes<\/li>\n<li>Power supply: 1 3.6 V lithium battery (non-replaceable)<\/li>\n<li>Battery life: 20 years (calculated)<\/li>\n<\/ul>\n<p>[\/et_pb_tab][et_pb_tab title=&#8221;Technical data AE5&#8243; _builder_version=&#8221;4.7.4&#8243; _module_preset=&#8221;default&#8221;]<\/p>\n<p><strong>Scope of application<\/strong><\/p>\n<ul class=\"stup-list\">\n<li>Honeywell residential, commercial and industrial membrane gas meters (BK-G..A, G1,6 to G100)<\/li>\n<li>Media: natural gas, city gas, propane, butane *, air, inert gases **<\/li>\n<li>Industries: gas industry<\/li>\n<li>Tasks: recording volume in measurement conditions, data transmission<br \/>* Gases according to EN 437<br \/>** Gases according to DVGW Code of Practice G260<\/li>\n<\/ul>\n<p><strong>Degree of protection<\/strong><\/p>\n<ul class=\"stup-list\">\n<li>IP 54<\/li>\n<\/ul>\n<p><strong>Room temperature<\/strong><\/p>\n<ul class=\"stup-list\">\n<li>-25 \u00b0 C up to + 55 \u00b0 C<\/li>\n<\/ul>\n<p><strong>Maximum operating pressure<\/strong><\/p>\n<ul class=\"stup-list\">\n<li>0.5 bar<\/li>\n<\/ul>\n<p><strong>Temperature compensation<\/strong><\/p>\n<ul class=\"stup-list\">\n<li>Supports mechanical temperature compensation<\/li>\n<\/ul>\n<p><strong>Current approvals<\/strong><\/p>\n<ul class=\"stup-list\">\n<li>MID class 1.5<\/li>\n<li>EN 1359<\/li>\n<li>ATEX<\/li>\n<li>CE<\/li>\n<li>EMC<\/li>\n<\/ul>\n<p><strong>Protection against unauthorized opening<\/strong><\/p>\n<ul class=\"stup-list\">\n<li>Digital rollers are individually scanned by opto-electronic means. The Absolute CODER is therefore not prone to failures caused by static magnetic fields<\/li>\n<li>The mechanical recording system in the measuring part of the gas meter is resistant to electromagnetic interference<\/li>\n<li>Unauthorized interference through the index view window can be checked by checking the pressure marks: The three small bars behind the index disc leave clearly visible marks on the index board when the index is pressed<\/li>\n<\/ul>\n<p><strong>Further features<\/strong><\/p>\n<ul class=\"stup-list\">\n<li>Robust battery-free design<\/li>\n<li>Optical reading<\/li>\n<li>Plug &amp; Play installation<\/li>\n<\/ul>\n<p>[\/et_pb_tab][et_pb_tab title=&#8221;Technical documentation&#8221; _builder_version=&#8221;4.7.4&#8243; _module_preset=&#8221;default&#8221;]<\/p>\n<ul class=\"documents-list\">\n<li><a href=\"http:\/\/fagas.ba\/fgs\/wp-content\/uploads\/2021\/01\/ZSD_1000487604_2_EN.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Absolute Encoder AE<\/a><\/li>\n<li><a href=\"http:\/\/fagas.ba\/fgs\/wp-content\/uploads\/2021\/01\/BA_ACM_M_Bus_wire_EN.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Communication module (ACMs)<\/a><\/li>\n<\/ul>\n<p>[\/et_pb_tab][\/et_pb_tabs][et_pb_divider color=&#8221;#D8D8D8&#8243; divider_position=&#8221;center&#8221; _builder_version=&#8221;4.7.4&#8243; _module_preset=&#8221;default&#8221;][\/et_pb_divider][et_pb_wc_related_products posts_number=&#8221;4&#8243; columns_number=&#8221;4&#8243; admin_label=&#8221;Sli\u010dni proizvodi&#8221; _builder_version=&#8221;4.7.4&#8243;][\/et_pb_wc_related_products][\/et_pb_column][\/et_pb_row][\/et_pb_section]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The Absolute ENCODER index for diaphragm gas meters consists of a mechanical index in which all 8 individual rollers are optically electronically scanned and read. The data is then continuously transmitted as a data word via a digital interface to the connected communication modules, ensuring continuous security of data transmission compared to conventional pulse transmission.<br \/>\nThe operating energy of the diaphragm meter is derived from the gas pressure. Electric power is only required to read the Absolute CODER, and the M-BUS master makes it available in the case of data transmission via cable. The M-BUS master is integrated in the electricity meter or data concentrator. No batteries are required for this application. In the case of radio data transmission, the battery in the communication module provides power. The &#8220;basic version&#8221; of the Absolute ENCODER AE5 is &#8220;smart reading&#8221; and can be retrofitted to cable or wireless communication modules even after network installation.<br \/>\nThe communication module is designed as a plug &amp; play solution and is easily connected and sealed to the ENCODER index. The connected receiver is synchronized automatically. The modular connection between the communication module and the ENCODER index allows the replacement of communication modules at any time without the need for additional programming. Therefore, the measuring part of the gas meter remains unchanged.<br \/>\nThe consistent modular design of Absolute ENCODER minimizes the effort and cost of installation, commissioning and data provision and ensures investment security for future applications.<br \/>\nThe following Absolute ENCODER communication modules (ACMs) are suitable for installation in the Absolute ENCODER AE5 and allow data transmission via cable or wireless transmission.<\/p>\n","protected":false},"featured_media":4239,"comment_status":"open","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"on","_et_pb_old_content":"The Absolute ENCODER index for diaphragm gas meters consists of a mechanical index in which all 8 individual rollers are optically electronically scanned and read. The data is then continuously transmitted as a data word via a digital interface to the connected communication modules, ensuring continuous security of data transmission compared to conventional pulse transmission.\nThe operating energy of the diaphragm meter is derived from the gas pressure. Electric power is only required to read the Absolute CODER, and the M-BUS master makes it available in the case of data transmission via cable. The M-BUS master is integrated in the electricity meter or data concentrator. No batteries are required for this application. In the case of radio data transmission, the battery in the communication module provides power. The \"basic version\" of the Absolute ENCODER AE5 is \"smart reading\" and can be retrofitted to cable or wireless communication modules even after network installation.\nThe communication module is designed as a plug & play solution and is easily connected and sealed to the ENCODER index. The connected receiver is synchronized automatically. The modular connection between the communication module and the ENCODER index allows the replacement of communication modules at any time without the need for additional programming. Therefore, the measuring part of the gas meter remains unchanged.\nThe consistent modular design of Absolute ENCODER minimizes the effort and cost of installation, commissioning and data provision and ensures investment security for future applications.\nThe following Absolute ENCODER communication modules (ACMs) are suitable for installation in the Absolute ENCODER AE5 and allow data transmission via cable or wireless transmission.","_et_gb_content_width":""},"product_cat":[320,340,368,342],"product_tag":[212,232,292,216],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v20.12 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>ABOLUTE-ENCODER AE5 - FAGAS<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/fagas.ba\/proizvod\/abolute-encoder-ae5\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ABOLUTE-ENCODER AE5 - FAGAS\" \/>\n<meta property=\"og:description\" content=\"The Absolute ENCODER index for diaphragm gas meters consists of a mechanical index in which all 8 individual rollers are optically electronically scanned and read. The data is then continuously transmitted as a data word via a digital interface to the connected communication modules, ensuring continuous security of data transmission compared to conventional pulse transmission. The operating energy of the diaphragm meter is derived from the gas pressure. Electric power is only required to read the Absolute CODER, and the M-BUS master makes it available in the case of data transmission via cable. The M-BUS master is integrated in the electricity meter or data concentrator. No batteries are required for this application. In the case of radio data transmission, the battery in the communication module provides power. The &quot;basic version&quot; of the Absolute ENCODER AE5 is &quot;smart reading&quot; and can be retrofitted to cable or wireless communication modules even after network installation. The communication module is designed as a plug &amp; play solution and is easily connected and sealed to the ENCODER index. The connected receiver is synchronized automatically. The modular connection between the communication module and the ENCODER index allows the replacement of communication modules at any time without the need for additional programming. Therefore, the measuring part of the gas meter remains unchanged. The consistent modular design of Absolute ENCODER minimizes the effort and cost of installation, commissioning and data provision and ensures investment security for future applications. The following Absolute ENCODER communication modules (ACMs) are suitable for installation in the Absolute ENCODER AE5 and allow data transmission via cable or wireless transmission.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/fagas.ba\/proizvod\/abolute-encoder-ae5\/\" \/>\n<meta property=\"og:site_name\" content=\"FAGAS\" \/>\n<meta property=\"article:modified_time\" content=\"2021-11-24T18:14:39+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/fagas.ba\/fgs\/wp-content\/uploads\/2021\/01\/2_ABOLUTE-ENCODER-AE5.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"640\" \/>\n\t<meta property=\"og:image:height\" content=\"399\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/fagas.ba\/proizvod\/abolute-encoder-ae5\/\",\"url\":\"https:\/\/fagas.ba\/proizvod\/abolute-encoder-ae5\/\",\"name\":\"ABOLUTE-ENCODER AE5 - FAGAS\",\"isPartOf\":{\"@id\":\"https:\/\/fagas.ba\/en\/#website\"},\"datePublished\":\"2021-11-24T18:14:38+00:00\",\"dateModified\":\"2021-11-24T18:14:39+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/fagas.ba\/proizvod\/abolute-encoder-ae5\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/fagas.ba\/proizvod\/abolute-encoder-ae5\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/fagas.ba\/proizvod\/abolute-encoder-ae5\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/fagas.ba\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\/\/fagas.ba\/en\/shop\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"ABOLUTE-ENCODER AE5\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/fagas.ba\/en\/#website\",\"url\":\"https:\/\/fagas.ba\/en\/\",\"name\":\"FAGAS\",\"description\":\"Projektovanje i proizvodnja gasne opreme\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/fagas.ba\/en\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ABOLUTE-ENCODER AE5 - FAGAS","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/fagas.ba\/proizvod\/abolute-encoder-ae5\/","og_locale":"en_US","og_type":"article","og_title":"ABOLUTE-ENCODER AE5 - FAGAS","og_description":"The Absolute ENCODER index for diaphragm gas meters consists of a mechanical index in which all 8 individual rollers are optically electronically scanned and read. The data is then continuously transmitted as a data word via a digital interface to the connected communication modules, ensuring continuous security of data transmission compared to conventional pulse transmission. The operating energy of the diaphragm meter is derived from the gas pressure. Electric power is only required to read the Absolute CODER, and the M-BUS master makes it available in the case of data transmission via cable. The M-BUS master is integrated in the electricity meter or data concentrator. No batteries are required for this application. In the case of radio data transmission, the battery in the communication module provides power. The \"basic version\" of the Absolute ENCODER AE5 is \"smart reading\" and can be retrofitted to cable or wireless communication modules even after network installation. The communication module is designed as a plug &amp; play solution and is easily connected and sealed to the ENCODER index. The connected receiver is synchronized automatically. The modular connection between the communication module and the ENCODER index allows the replacement of communication modules at any time without the need for additional programming. Therefore, the measuring part of the gas meter remains unchanged. The consistent modular design of Absolute ENCODER minimizes the effort and cost of installation, commissioning and data provision and ensures investment security for future applications. The following Absolute ENCODER communication modules (ACMs) are suitable for installation in the Absolute ENCODER AE5 and allow data transmission via cable or wireless transmission.","og_url":"https:\/\/fagas.ba\/proizvod\/abolute-encoder-ae5\/","og_site_name":"FAGAS","article_modified_time":"2021-11-24T18:14:39+00:00","og_image":[{"width":640,"height":399,"url":"https:\/\/fagas.ba\/fgs\/wp-content\/uploads\/2021\/01\/2_ABOLUTE-ENCODER-AE5.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/fagas.ba\/proizvod\/abolute-encoder-ae5\/","url":"https:\/\/fagas.ba\/proizvod\/abolute-encoder-ae5\/","name":"ABOLUTE-ENCODER AE5 - FAGAS","isPartOf":{"@id":"https:\/\/fagas.ba\/en\/#website"},"datePublished":"2021-11-24T18:14:38+00:00","dateModified":"2021-11-24T18:14:39+00:00","breadcrumb":{"@id":"https:\/\/fagas.ba\/proizvod\/abolute-encoder-ae5\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/fagas.ba\/proizvod\/abolute-encoder-ae5\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/fagas.ba\/proizvod\/abolute-encoder-ae5\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/fagas.ba\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/fagas.ba\/en\/shop\/"},{"@type":"ListItem","position":3,"name":"ABOLUTE-ENCODER AE5"}]},{"@type":"WebSite","@id":"https:\/\/fagas.ba\/en\/#website","url":"https:\/\/fagas.ba\/en\/","name":"FAGAS","description":"Projektovanje i proizvodnja gasne opreme","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/fagas.ba\/en\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/fagas.ba\/en\/wp-json\/wp\/v2\/product\/5240"}],"collection":[{"href":"https:\/\/fagas.ba\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/fagas.ba\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/fagas.ba\/en\/wp-json\/wp\/v2\/comments?post=5240"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/fagas.ba\/en\/wp-json\/wp\/v2\/media\/4239"}],"wp:attachment":[{"href":"https:\/\/fagas.ba\/en\/wp-json\/wp\/v2\/media?parent=5240"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/fagas.ba\/en\/wp-json\/wp\/v2\/product_cat?post=5240"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/fagas.ba\/en\/wp-json\/wp\/v2\/product_tag?post=5240"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}